Supplying you with customized 300/500v xlpe insulated lszh sheathed flame retardant power cables (single core), it is one of the reliable 300/500v xlpe insulated lszh sheathed flame retardant power cables (single core) manufacturers and suppliers, welcome to wholesale our products at good price from our factory.
300/500V XLPE Insulated LSZH sheathed Flame retardant Power Cables (single core)
Application: |
The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings. |
Standard: |
Basic design to IEC 60502-1 |
APPLICATION
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases |
NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING 300/500V
CABLE CONSTRUCTION
Conductor:
1.Plain annealed copper wire, stranded according to IEC(EN) 60228 class
2.Insulation: Extruded cross-linked XLPE compound.
3.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
COLOUR CODE
Insulation colour as per bs7671
with earth conductor |
without earth conductor |
|
2Cores |
- |
Brown,Blue |
3Cores |
Yellow/Green,Brown,Blue |
Brown,Gray,Black |
4Cores |
Yellow/Green,Brown,Gray,Black |
Brown,Gray,Black,Blue |
5Cores |
Yellow/Green,Brown,Gray,Black,Blue |
Brown,Gray,Black,Blue,Black |
above 5 Cores |
Yellow/Green,Black Numbered |
Black Numbered |
sheath colour: Black
Physical AND THERMAL PROPERTIES
Temperature range during operation: Max.90°C for XLPE 250°C in short-circuit for 5s max. Minimum bending radius: 6 x Overall Diameter (unarmoured cable) 10 x Overall Diameter (armoured cable) SWB Steel wire braid
CONSTRUCTION PARAMETERS
Conductor |
||||
No. of Core X Cross Section |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Overall Diameter |
Approx. Weight |
Noxmm2 |
No./mm |
mm |
mm |
kg/km |
1x1.5 |
7/0.53 |
0.50 |
3.8 |
27 |
1x2.5 |
7/0.67 |
0.50 |
4.2 |
37 |
1x4.0 |
7/0.85 |
0.50 |
4.8 |
54 |
Electrical PROPERTIES
Conductor Operating Temperature : 90°C Ambient Temperature : 30°C Current-Carrying Capacities (Amp)
Conductor crosssectional area |
Reference Method 4 (enclosed in conduit in thermally insulating wall etc) |
Reference Method 3 (enclosed in conduit on a wall or in trunking etc) |
Reference Method 1 (clipped direct) |
Reference Method 11 (on a perforated cable tray, horizontal or vertical) |
Reference Method 12 (free air) |
||||||
Horizontal flat spaced |
Vertical flat spaced |
Trefoil |
|||||||||
2 cables, single- phase a.c. or d.c. |
3 or 4 cables, 3-phase a.c. |
2 cables, single- phase a.c. or d.c |
3 or 4 cables, 3-phase a.c. |
2 cables, single- phase a.c. or d.c. flat and touching |
3 or 4 cables, 3-phase a.c. flat and touching or trefoil |
2 cables, single- phase a.c. or d.c. or flat and touching |
3 or 4 cables, 3-phase a.c. flat and touching or trefoil |
2 cables, single- phase a.c. or d.c. or 3 c ables three phase |
2 cables, single- phase a.c. or d.c. or 3 cables three phase |
3 cables, trefoil 3-phase a.c. |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
mm2 |
A |
A |
A |
A |
A |
A |
A |
A |
A |
A |
A |
1.5 |
18 |
17 |
22 |
19 |
25 |
23 |
- |
- |
- |
- |
- |
2.5 |
24 |
23 |
30 |
26 |
34 |
31 |
- |
- |
- |
- |
- |
4 |
33 |
30 |
40 |
35 |
46 |
41 |
- |
- |
- |
- |
- |
Voltage Drop (Per Amp Per Meter)
Nominal Cross Section Area |
2 cables d.c. |
2 cables, single-phase a.c. |
3 or 4 cables, 3-phase a.c. |
|||
Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) |
Ref. Methods 1 and 11 (clipped direct or on trays touching) |
Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) |
Ref. Methods 1, 11 and 12 (in trefoil) |
Ref. Methods 1 and 11(Flat and touching) |
||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
mm2 |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
1.5 |
31 |
31 |
27 |
27 |
27 |
27 |
2.5 |
19 |
19 |
16 |
16 |
16 |
16 |
4 |
33 |
12 |
10 |
10 |
10 |
10 |