CONTEC CMS7000 PLUS 12.1inch LCD Touch Screen ICU Patient Monitor


Introduction


This Patient Monitoring Device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.


Functions


Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP

1-ECG Heart rate(HR): ECG waveform; Arrhythmia and ST-segment analysis.

2-RESP Respiration rate(RR): Respiration waveform

3-SpO2 Oxygen saturation(SpO2): Plethysmogram(PLETH) waveform; Pulse rate(PR); Bar graph.

4-NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)

5-TEMP T1, T2, TD

This Patient Monitoring Device has abundant functions, such as touch-screen operation, audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.


Features


1)12.1" TFT color LCD, multi-language interface (English, Chinese, Russian, Kazakhstan, Czech, Slovak).

2)Touch screen operation, which improves the working efficiency for medical staff.

3)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.

4)all-round monitor for adult, pediatric and neonate.

5)With the standard interface, big character interface and view bed, convenient to observe.

6)Waveform, parameter color and location can be set optionally.

7)Maximum 8-channel waveform synchronous display

8)Display a 7-lead ECG waveform on one screen.

9)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak flling.

10)NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data.

11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.

12)Drug concentration calculation and titration table functions.

13)Connect to Central Monitoring System by 3G, Wi-Fi, or wired mode.

14)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.

15)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).



Performance



▲ECG

Lead mode

3-lead or 5-lead

Lead selection

I, II, III, aVR, aVL, aVF, V

Waveform

5-lead, dual-channel

3-lead, single-channel

Gain

2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV

Scan speed

12.5mm/s, 25 mm/s, 50 mm/s

HR


Measurement and alarm range

15~350 bpm

Accuracy

±1 % or ±1 bpm, whichever is greater

Alarm accuracy

± 2 bpm

Resolution

1 bpm

ST-segment monitoring


Measurement and alarm range

-2 mV ~ +2 mV

Accuracy

-0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater

Other range

unspecified

Arrhythmia analysis

ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Pacemaker

yes


▲RESP

Method

R-F(RA-LL) Impedance

Respiration rate


Measurement and alarm range

0~150 rpm

Resolution

1 rpm

Measurement accuracy

±2 rpm

Alarm accuracy

±3 rpm

Apnea alarm

10~40s

Scan speed

6.25 mm/s, 12.5 mm/s, 25 mm/s


▲NIBP

Method

Oscillometry

Mode

Manual/AUTO/Continuous

Measurement interval in AUTO mode

1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes

Measurement period in Continuous mode

5 minutes

Measurement and alarm range

10 ~ 270 mmHg

Resolution

1 mmHg

Cuff pressure accuracy

±3 mmHg

Measurement accuracy


Maximal mean deviation

±5 mmHg

Maximal standard deviation

8 mmHg

Over-pressure protection


Adult mode

297±3 mmHg

Pediatric mode

240±3 mmHg

Neonatal mode

147±3 mmHg


▲SpO2

Measurement and alarm range

0 ~ 100%

Resolution

1%

Measurement accuracy

70%~100%: ±2%;

0%~69%

unspecified


▲PR

Measurement and alarm range

30 ~ 250 bpm

Measurement accuracy

±2 bpm or ±2%, whichever is greater


▲TEMP

Channel

dual-channel

Measurement and alarm range

0 ~ 50℃

Resolution

0.1 ℃

Accuracy

±0.1 ℃


▲EtCO2

Method

Sidestream or Mainstream

Measuring Range

0~150mmHg

Resolution

0~69 mmHg, 0.1 mmHg

70~150 mmHg, 0.25 mmHg

Accuracy

0~40 mm Hg ±2 mm Hg

41~70 mm Hg ±5%

71~100 mm Hg ±8%

101~150 mm Hg ±10%

AwRR Range

2~150 rpm

AwRR Accuracy

±1BPM

Apnea Alarm

Yes


▲IBP

Channel

dual-channel

Label

ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and Alarm Range

-10~300 mmHg

Resolution 1 mmHg


Accuracy

±2% or 1mmHg, whichever is greater

▲Power supply

220 V, 50 Hz

▲Safety classification

Class I, type CF defibrillation-proof applied part


Accessories


1)Adult fingertip SpO2 probe (5-pin)

2)Adult NIBP cuff

3)NIBP extension tube

4)ECG lead cable

5)ECG electrode

6)Temperature probe

7)Power cord

8)User Manual


Physical characteristic


Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H)

Weight: 3.6 Kg


About us


Our product line covers a wide range of 13 categories. Our products - patient monitoring devices have been distributed to over 80 countries and regions, and Contec has become one of the most recognized brands in the medical industry.



http://www.contecmedsystems.com/

Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]